SAC-SINGLAS Accredited · ISO/IEC 17025

Humidity / RH Transmitter Calibration in Singapore

Unitest calibrates relative humidity (RH) transmitters in Singapore across 5% to 90% RH at 5 °C to 50 °C, under SAC-SINGLAS accreditation LA-2023-0845-C (ISO/IEC 17025). Standard turnaround is 5–7 working days; express service is 2–3 days, with free collection and delivery in Singapore for orders above $300.

Also known as: Relative Humidity Transmitter · RH Transmitter · Humidity Sensor

Why calibrate?

Unitest calibrates relative humidity (RH) transmitters in Singapore over a range of 5% to 90% RH, with traceable ISO/IEC 17025 certificates. Calibration verifies both the sensor polymer-film response and the signal output accuracy.

What you receive

What humidity / RH transmitter calibration at Unitest covers

Traceable certificate

Calibration certificate with an unbroken traceability chain to national and international standards, recording the as-found condition before any adjustment.

Stated uncertainty

Results reported with measurement uncertainty, so you know exactly how much confidence each reading carries in your quality system.

5–7 day turnaround

Standard turnaround 5–7 working days; express 2–3 working days on request. Free collection and delivery within Singapore for orders above S$300.

Part of our humidity calibration service, accredited under SAC-SINGLAS LA-2023-0845-C.

How often

How often should a humidity / RH transmitter be calibrated?

Humidity transmitters should be calibrated every 12 months, or more frequently in aggressive environments where the sensor may degrade faster.

Accredited ranges

Humidity / RH Transmitter calibration ranges & measurement uncertainty

The parameters, ranges and calibration & measurement capability (CMC) below are taken from our SAC-SINGLAS Schedule of Accreditation (LA-2023-0845-C, to ISO/IEC 17025). CMC is the smallest measurement uncertainty we can achieve under accredited conditions.

Humidity / Temperature measuring instruments (Lab / Site, Used Reference Probe)· UNI-T009 Rev:0
Range / measured quantityMeasurement uncertainty (CMC)
Temperature: 5 °C – 50 °C0.3 °C
Humidity: (5 – 90) % relative humidity2.4 % relative humidity
Humidity / Temperature measuring instruments (Lab, Used Chilled Mirror)· UNI-T009 Rev:0
Range / measured quantityMeasurement uncertainty (CMC)
Temperature 15 °C – 50 °C0.2 °C
Humidity (40 – 90) % relative humidity1.2 % relative humidity
Fixed Temperature @23°C (05 – 50) % relative humidity0.7 % relative humidity
Fixed Temperature @23°C (50 – 90) % relative humidity1.1 % relative humidity
Download the full SINGLAS Schedule (LA-2023-0845-C) — PDF

You can also verify our accreditation on the SAC-SINGLAS directory.

Questions

Humidity / RH Transmitter calibration FAQ

How often should a humidity / RH transmitter be calibrated?

Humidity transmitters should be calibrated every 12 months, or more frequently in aggressive environments where the sensor may degrade faster.

Is humidity / RH transmitter calibration accredited?

Yes. Humidity / RH Transmitter calibration is covered under our SAC-SINGLAS scope of accreditation (LA-2023-0845-C, ISO/IEC 17025), covering 5% to 90% RH at 5 °C to 50 °C. Certificates state the measured values and measurement uncertainty, traceable to national and international standards. Where an instrument falls outside the accredited ranges, we can calibrate it as a traceable service instead.

How long does humidity / RH transmitter calibration take?

Standard turnaround is 5 to 7 working days; express service is 2 to 3 working days. Collection and delivery in Singapore are free for orders above $300.

Can you calibrate my brand of humidity / RH transmitter?

Almost certainly — the makes listed on this site are simply the ones customers most commonly send in. Send us the make and model and our engineers will confirm whether it falls within our accredited scope or can be calibrated as a traceable service.

Related

Related instruments

Thermo-Hygrometer (RH & Temperature)

Thermo-Hygrometer calibration →

Browse every instrument type on the Find Your Instrument page.

Need humidity / RH transmitter calibration?

Submit your instrument list — we'll confirm capability, turnaround and pricing, no obligation.

Get a QuoteWhatsApp