SAC-SINGLAS Accredited · ISO/IEC 17025
Analog Multimeter Calibration in Singapore
Unitest calibrates analog (pointer-type) multimeters in Singapore across DC/AC voltage to 1020 V, DC/AC current to 30 A and resistance to 1200 MΩ, under SAC-SINGLAS accreditation LA-2023-0845-C (ISO/IEC 17025). Standard turnaround is 5–7 working days; express service is 2–3 days, with free collection and delivery in Singapore for orders above $300.
Also known as: Analog-Type Multimeter · Pointer Multimeter · Analogue Multimeter
Why calibrate?
Unitest calibrates analog (pointer-type) multimeters in Singapore for DC/AC voltage, current and resistance, with traceable ISO/IEC 17025 certificates. Analog meters are sensitive to mechanical shock and drift. Regular calibration confirms the pointer scale remains accurate.
What you receive
What analog multimeter calibration at Unitest covers
Traceable certificate
Calibration certificate with an unbroken traceability chain to national and international standards, recording the as-found condition before any adjustment.
Stated uncertainty
Results reported with measurement uncertainty, so you know exactly how much confidence each reading carries in your quality system.
5–7 day turnaround
Standard turnaround 5–7 working days; express 2–3 working days on request. Free collection and delivery within Singapore for orders above S$300.
Part of our electrical calibration service, accredited under SAC-SINGLAS LA-2023-0845-C.
How often
How often should a analog multimeter be calibrated?
Analog multimeters should be calibrated at least every 12 months. Instruments used in critical applications may need 6-monthly checks.
Accredited ranges
Analog Multimeter calibration ranges & measurement uncertainty
The parameters, ranges and calibration & measurement capability (CMC) below are taken from our SAC-SINGLAS Schedule of Accreditation (LA-2023-0845-C, to ISO/IEC 17025). CMC is the smallest measurement uncertainty we can achieve under accredited conditions.
DC Voltage measuring instrument· UNI-E001 Rev:1
| Range / measured quantity | Measurement uncertainty (CMC) |
|---|---|
| 0 mV – 220 mV | 0.0022 mV |
| >220 mV – 2.2 V | 0.012 mV |
| >2.2 V – 11 V | 0.043 mV |
| >11 V – 22 V | 0.084 mV |
| >22 V – 220 V | 0.0012 V |
| >220 V – 1020 V | 0.0079 V |
AC Voltage measuring instruments· UNI-E001 Rev:1
| Range / measured quantity | Measurement uncertainty (CMC) |
|---|---|
| 1 mV – 2.2 mV, 3 Hz to 5 Hz | 1.6 % |
| 1 mV – 2.2 mV, >5 Hz to 10 Hz | 1.0 % |
| 1 mV – 2.2 mV, >10 Hz to 20 Hz | 0.0046 mV |
| 1 mV – 2.2 mV, >20 Hz to 40 Hz | 0.0043 mV |
| 1 mV – 2.2 mV, >40 Hz to 20 kHz | 0.0043 mV |
| 1 mV – 2.2 mV, >20 kHz to 50 kHz | 0.0046 mV |
| 1 mV – 2.2 mV, >50 kHz to 100 kHz | 0.0062 mV |
| 1 mV – 2.2 mV, >100 kHz to 300 kHz | 0.02 mV |
| 1 mV – 2.2 mV, >300 kHz to 500 kHz | 0.03 mV |
| 1 mV – 2.2 mV, >500 kHz to 1 MHz | 0.03 mV |
| 2.2 mV to 22 mV, 3 Hz to 5 Hz | 0.32 % |
| 2.2 mV to 22 mV, >5 Hz to 10 Hz | 0.17 % |
| 2.2 mV to 22 mV, >10 Hz to 20 Hz | 0.01 mV |
| 2.2 mV to 22 mV, >20 Hz to 40 Hz | 0.01 mV |
| 2.2 mV to 22 mV, >40 Hz to 20 kHz | 0.006 mV |
| 2.2 mV to 22 mV, >20 kHz to 50 kHz | 0.009 mV |
| 2.2 mV to 22 mV, >50 kHz to 100 kHz | 0.02 mV |
| 2.2 mV to 22 mV, >100 kHz to 300 kHz | 0.04 mV |
| 2.2 mV to 22 mV, >300 kHz to 500 kHz | 0.06 mV |
| 2.2 mV to 22 mV, >500 kHz to 1 MHz | 0.081 mV |
| 22 mV to 220 mV, 3 Hz to 5 Hz | 0.42 % |
| 22 mV to 220 mV, >5 Hz to 10 Hz | 0.15 % |
| 22 mV to 220 mV, >10 Hz to 20 Hz | 0.066 mV |
| 22 mV to 220 mV, >20 Hz to 40 Hz | 0.028 mV |
| 22 mV to 220 mV, >40 Hz to 20 kHz | 0.021 mV |
| 22 mV to 220 mV, >20 kHz to 50 kHz | 0.035 mV |
| 22 mV to 220 mV, >50 kHz to 100 kHz | 0.086 mV |
| 22 mV to 220 mV, >100 kHz to 300 kHz | 0.17 mV |
| 22 mV to 220 mV, >300 kHz to 500 kHz | 0.34 mV |
| 22 mV to 220 mV, >500 kHz to 1 MHz | 0.65 mV |
| 220 mV to 2.2 V, 3 Hz to 5 Hz | 0.33 % |
| 220 mV to 2.2 V, >5 Hz to 10 Hz | 0.5 % |
| 220 mV to 2.2 V, >10 Hz to 20 Hz | 0.58 mV |
| 220 mV to 2.2 V, >20 Hz to 40 Hz | 0.22 mV |
| 220 mV to 2.2 V, >40 Hz to 20 kHz | 0.11 mV |
| 220 mV to 2.2 V, >20 kHz to 50 kHz | 0.17 mV |
| 220 mV to 2.2 V, >50 kHz to 100 kHz | 0.23 mV |
| 220 mV to 2.2 V, >100 kHz to 300 kHz | 0.86 mV |
| 220 mV to 2.2 V, >300 kHz to 500 kHz | 0.0025 V |
| 220 mV to 2.2 V, >500 kHz to 1 MHz | 0.0042 V |
| 2.2 V to 22 V, 3 Hz to 5 Hz | 0.32 % |
| 2.2 V to 22 V, >5 Hz to 10 Hz | 0.50 % |
| 2.2 V to 22 V, >10 Hz to 20 Hz | 0.0057 V |
| 2.2 V to 22 V, >20 Hz to 40 Hz | 0.0022 V |
| 2.2 V to 22 V, >40 Hz to 20 kHz | 0.0011 V |
| 2.2 V to 22 V, >20 kHz to 50 kHz | 0.0016 V |
| 2.2 V to 22 V, >50 kHz to 100 kHz | 0.0021 V |
| 2.2 V to 22 V, >100 kHz to 300 kHz | 0.0067 V |
| 2.2 V to 22 V, >300 kHz to 500 kHz | 0.025 V |
| 2.2 V to 22 V, >500 kHz to 1 MHz | 0.038 V |
| 22 V to 220 V, 3 Hz to 5 Hz | 0.50 % |
| 22 V to 220 V, >5 Hz to 10 Hz | 0.16 % |
| 22 V to 220 V, >10 Hz to 20 Hz | 0.058 V |
| 22 V to 220 V, >20 Hz to 40 Hz | 0.022 V |
| 22 V to 220 V, >40 Hz to 20 kHz | 0.013 V |
| 22 V to 220 V, >20 kHz to 50 kHz | 0.019 V |
| 22 V to 220 V, >50 kHz to 100 kHz | 0.036 V |
| 220 V to 1020 V, 3 Hz to 5 Hz | 0.29 % |
| 220 V to 1020 V, >5 Hz to 10 Hz | 0.12 % |
| 220 V to 1020 V, >10 Hz to 50 Hz | 0.12 % |
| 220 V to 1020 V, >50 Hz to 1 kHz | 0.085 V |
| 220 V to 1020 V, >1 kHz – 10 kHz | 0.04 % |
DC Current measuring instruments· UNI-E001 Rev:1
| Range / measured quantity | Measurement uncertainty (CMC) |
|---|---|
| 0 µA – 220 µA | 0.015 µA |
| >220 µA – 2.2 mA | 0.09 µA |
| >2.2 mA – 22 mA | 0.83 µA |
| >22 mA – 220 mA | 0.011 mA |
| >220 mA – 2.2 A | 0.2 mA |
| >2.2 A – 3.1 A | 0.044 % |
| >3.1 A – 12 A | 0.041 % |
| >12 A – 30 A | 0.11 % |
AC Current measuring instruments· UNI-E001 Rev:1
| Range / measured quantity | Measurement uncertainty (CMC) |
|---|---|
| 20 µA – 220 µA, 10 Hz – 20 Hz | 0.08 µA |
| 20 µA – 220 µA, >20 Hz – 40 Hz | 0.06 µA |
| 20 µA – 220 µA, >40 Hz – 1 kHz | 0.040 µA |
| 20 µA – 220 µA, >1 kHz – 5 kHz | 0.030 µA |
| 20 µA – 220 µA, >5 kHz – 10 kHz | 0.12 µA |
| 20 µA – 220 µA, >10 kHz – 30 kHz | 3.4 % |
| 220 µA – 2.2 mA, >10 Hz – 20 Hz | 0.62 µA |
| 220 µA – 2.2 mA, >20 Hz – 40 Hz | 0.51 µA |
| 220 µA – 2.2 mA, >40 Hz – 1 kHz | 0.28 µA |
| 220 µA – 2.2 mA, >1 kHz – 5 kHz | 0.6 µA |
| 220 µA – 2.2 mA, >5 kHz – 10 kHz | 0.0032 mA |
| 220 µA – 2.2 mA, >10 kHz – 30 kHz | 4.8 % |
| 2.2 mA – 22 mA, 10 Hz – 20 Hz | 0.007 mA |
| 2.2 mA – 22 mA, >20 Hz – 40 Hz | 0.004 mA |
| 2.2 mA – 22 mA, >40 Hz – 1 kHz | 0.003 mA |
| 2.2 mA – 22 mA, >1 kHz – 5 kHz | 0.006 mA |
| 2.2 mA – 22 mA, >5 kHz – 10 kHz | 0.030 mA |
| 2.2 mA – 22 mA, >10 kHz – 30 kHz | 1.4 % |
| 22 mA – 220 mA, 10 Hz – 20 Hz | 0.061 mA |
| 22 mA – 220 mA, >20 Hz – 40 Hz | 0.04 mA |
| 22 mA – 220 mA, >40 Hz – 1 kHz | 0.027 mA |
| 22 mA – 220 mA, >1 kHz – 5 kHz | 0.06 mA |
| 22 mA – 220 mA, >5 kHz – 10 kHz | 0.26 mA |
| 22 mA – 220 mA, >10 kHz – 30 kHz | 1.4 % |
| 220 mA – 2.2 A, 20 Hz – 1 kHz | 0.59 mA |
| 220 mA – 2.2 A, >1 kHz – 5 kHz | 1.2 mA |
| 220 mA – 2.2 A, >5 kHz – 10 kHz | 0.016 A |
| 220 mA – 2.2 A, >10 kHz to 30 kHz | 0.8 % |
| 2.2 A – 3.1 A, 3 Hz – 45 Hz | 0.25 % |
| 2.2 A – 3.1 A, >45 Hz – 1 kHz | 0.06 % |
| 2.2 A – 3.1 A, >1 kHz – 5 kHz | 0.06 % |
| 2.2 A – 3.1 A, >5 kHz – 10 kHz | 0.3 % |
| 3.1 A – 12 A, 3 Hz – 45 Hz | 0.12 % |
| 3.1 A – 12 A, >45 Hz – 1 kHz | 0.05 % |
| 3.1 A – 12 A, >1 kHz – 5 kHz | 0.07 % |
| 3.1 A – 12 A, >5 kHz – 10 kHz | 0.29 % |
| 12 A – 30.2 A, 3 Hz – 45 Hz | 0.21 % |
| 12 A – 30.2 A, >45 Hz – 1 kHz | 0.14 % |
| 12 A – 30.2 A, >1 kHz – 5 kHz | 0.57 % |
Resistance measuring instrument· UNI-E001 Rev:1
| Range / measured quantity | Measurement uncertainty (CMC) |
|---|---|
| 0 Ω – 12 Ω | 0.011 Ω |
| >12 Ω – 120 Ω | 0.13 % |
| >120 Ω – 1.2 kΩ | 0.11 % |
| >1.2 kΩ – 12 kΩ | 0.019 % |
| >12 kΩ – 120 kΩ | 0.011 % |
| >120 kΩ – 1.2 MΩ | 0.011 % |
| >1.2 MΩ – 12 MΩ | 0.021 % |
| >12 MΩ – 120 MΩ | 0.062 % |
| >120 MΩ – 1200 MΩ | 0.42 % |
You can also verify our accreditation on the SAC-SINGLAS directory.
Questions
Analog Multimeter calibration FAQ
How often should a analog multimeter be calibrated?
Analog multimeters should be calibrated at least every 12 months. Instruments used in critical applications may need 6-monthly checks.
Is analog multimeter calibration accredited?
Yes. Analog Multimeter calibration is covered under our SAC-SINGLAS scope of accreditation (LA-2023-0845-C, ISO/IEC 17025), covering DC/AC voltage to 1020 V, DC/AC current to 30 A and resistance to 1200 MΩ. Certificates state the measured values and measurement uncertainty, traceable to national and international standards. Where an instrument falls outside the accredited ranges, we can calibrate it as a traceable service instead.
How long does analog multimeter calibration take?
Standard turnaround is 5 to 7 working days; express service is 2 to 3 working days. Collection and delivery in Singapore are free for orders above $300.
Can you calibrate my brand of analog multimeter?
Almost certainly. The makes listed on this site are simply the ones customers most commonly send in. Send us the make and model and our engineers will confirm whether it falls within our accredited scope or can be calibrated as a traceable service.
Related
Related instruments
Digital Multimeter (DMM)
Digital Multimeter calibration →Clamp Meter
Clamp Meter calibration →Insulation Resistance Tester
Insulation Resistance Tester calibration →Browse every instrument type on the Find Your Instrument page.
Need analog multimeter calibration?
Submit your instrument list and we'll confirm capability, turnaround and pricing, no obligation.