RTD / PT100 Temperature Sensor Calibration in Singapore
Unitest calibrates RTD and PT100 temperature sensors in Singapore across -95 °C to 660 °C, under SAC-SINGLAS accreditation LA-2023-0845-C (ISO/IEC 17025). Standard turnaround is 5–7 working days; express service is 2–3 days, with free collection and delivery in Singapore for orders above $300.
Also known as: RTD Resistance Thermometer · PT100 Sensor · Resistance Temperature Detector
Why calibrate?
Unitest calibrates RTDs (resistance temperature detectors) and PT100/PT385 sensors in Singapore over a range of -95°C to 660°C, with SAC-SINGLAS accredited ISO/IEC 17025 certificates. RTD resistance shifts gradually with repeated thermal cycling, mechanical stress and contamination; calibration confirms the resistance-temperature relationship is still accurate and the traceability chain is intact for process control and regulatory submissions.
What you receive
What RTD / PT100 temperature sensor calibration at Unitest covers
Traceable certificate
Calibration certificate with an unbroken traceability chain to national and international standards, recording the as-found condition before any adjustment.
Stated uncertainty
Results reported with measurement uncertainty, so you know exactly how much confidence each reading carries in your quality system.
5–7 day turnaround
Standard turnaround 5–7 working days; express 2–3 working days on request. Free collection and delivery within Singapore for orders above S$300.
Part of our temperature calibration service, accredited under SAC-SINGLAS LA-2023-0845-C.
How often
How often should a RTD / PT100 temperature sensor be calibrated?
RTDs are typically calibrated every 12 months. Critical pharmaceutical or food-safety applications should follow a 6-monthly schedule.
Accredited ranges
RTD / PT100 Temperature Sensor calibration ranges & measurement uncertainty
The parameters, ranges and calibration & measurement capability (CMC) below are taken from our SAC-SINGLAS Schedule of Accreditation (LA-2023-0845-C, to ISO/IEC 17025). CMC is the smallest measurement uncertainty we can achieve under accredited conditions.
RTD, PRT Sensor with Indicator & Temperature Measuring instruments (Lab)· UNI-T001 Rev:0
| Range / measured quantity | Measurement uncertainty (CMC) |
|---|---|
| -80 °C – -40 °C | 0.011 °C |
| >-40 °C – 0 °C | 0.01 °C |
| >0 °C – 50 °C | 0.01 °C |
| >50 °C – 140 °C | 0.01 °C |
| >140 °C – 210 °C | 0.01 °C |
| >210 °C – 270 °C | 0.011 °C |
| >270 °C – 450 °C | 0.018 °C |
| >450 °C – 500 °C | 0.02 °C |
| >500 °C – 660 °C | 0.39 °C |
RTD, PRT Sensor with Indicator & Temperature Measuring instruments (Site)· UNI-T001 Rev:0
| Range / measured quantity | Measurement uncertainty (CMC) |
|---|---|
| -95 °C – 0 °C | 0.066 °C |
| >0 °C – 60 °C | 0.033 °C |
| >60 °C – 140 °C | 0.047 °C |
| >140 °C – 270 °C | 0.26 °C |
| >270 °C – 450 °C | 0.33 °C |
| >450 °C – 660 ° | 0.39 °C |
RTD Sensor without Indicator, PRT Sensor without Indicator & Temperature measuring instruments (Lab)· UNI-T003 Rev:0
| Range / measured quantity | Measurement uncertainty (CMC) |
|---|---|
| -80 °C - -40 °C | 0.01 °C |
| >-40 °C – 0°C | 0.01 °C |
| >0 °C – 50 °C | 0.01 °C |
| >50 °C – 140 °C | 0.012 °C |
| >140 °C – 210 °C | 0.012 °C |
| >210 °C – 270 °C | 0.02 °C |
| >270 °C – 500 °C | 0.03 °C |
| >500 °C – 660 °C | 0.39 °C |
RTD Sensor without Indicator, PRT Sensor without Indicator & Temperature measuring instruments (Site)· UNI-T003 Rev:0
| Range / measured quantity | Measurement uncertainty (CMC) |
|---|---|
| -95 °C – 60 °C | 0.6 °C |
| >60 °C – 140 °C | 0.35 °C |
| >140 °C – 270 °C | 0.43 °C |
| >270 °C – 450 °C | 0.47 °C |
| >450 °C – 660 °C | 0.52 °C |
You can also verify our accreditation on the SAC-SINGLAS directory.
Questions
RTD / PT100 Temperature Sensor calibration FAQ
How often should a RTD / PT100 temperature sensor be calibrated?
RTDs are typically calibrated every 12 months. Critical pharmaceutical or food-safety applications should follow a 6-monthly schedule.
Is RTD / PT100 temperature sensor calibration accredited?
Yes. RTD / PT100 Temperature Sensor calibration is covered under our SAC-SINGLAS scope of accreditation (LA-2023-0845-C, ISO/IEC 17025), covering -95 °C to 660 °C. Certificates state the measured values and measurement uncertainty, traceable to national and international standards. Where an instrument falls outside the accredited ranges, we can calibrate it as a traceable service instead.
How long does RTD / PT100 temperature sensor calibration take?
Standard turnaround is 5 to 7 working days; express service is 2 to 3 working days. Collection and delivery in Singapore are free for orders above $300.
Can you calibrate my brand of RTD / PT100 temperature sensor?
Almost certainly — the makes listed on this site are simply the ones customers most commonly send in. Send us the make and model and our engineers will confirm whether it falls within our accredited scope or can be calibrated as a traceable service.
Related
Related instruments
Thermocouple
Thermocouple calibration →Thermistor Temperature Sensor
Thermistor Temperature Sensor calibration →Dry Block / Dry Well Calibrator
Dry Block / Dry Well Calibrator calibration →Browse every instrument type on the Find Your Instrument page.
Need RTD / PT100 temperature sensor calibration?
Submit your instrument list — we'll confirm capability, turnaround and pricing, no obligation.