Bench Multimeter (Precision) Calibration in Singapore

Unitest calibrates high-precision bench multimeters in Singapore — including Keysight — across DC/AC voltage to 1020 V, DC/AC current to 30 A, resistance to 1200 MΩ and frequency to 2 MHz, under SAC-SINGLAS accreditation LA-2023-0845-C (ISO/IEC 17025). Standard turnaround is 5–7 working days; express service is 2–3 days, with free collection and delivery in Singapore for orders above $300.

Also known as: High-Precision Bench Multimeter · 6.5-Digit Multimeter · Bench DMM

Why calibrate?

Unitest calibrates high-precision bench multimeters (5.5- and 6.5-digit) in Singapore, covering DC and AC voltage (to 1020 V), DC and AC current, resistance and frequency, with SAC-SINGLAS accredited ISO/IEC 17025 certificates. Bench multimeters used as working standards in calibration labs must carry current traceable calibration.

What you receive

What bench multimeter (precision) calibration at Unitest covers

Traceable certificate

Calibration certificate with an unbroken traceability chain to national and international standards, recording the as-found condition before any adjustment.

Stated uncertainty

Results reported with measurement uncertainty, so you know exactly how much confidence each reading carries in your quality system.

5–7 day turnaround

Standard turnaround 5–7 working days; express 2–3 working days on request. Free collection and delivery within Singapore for orders above S$300.

Part of our electrical calibration service, accredited under SAC-SINGLAS LA-2023-0845-C.

How often

How often should a bench multimeter (precision) be calibrated?

Precision bench multimeters are typically calibrated every 12 months. Units used as in-house reference standards may be calibrated every 6 months to tighten the uncertainty budget.

Accredited ranges

Bench Multimeter (Precision) calibration ranges & measurement uncertainty

The parameters, ranges and calibration & measurement capability (CMC) below are taken from our SAC-SINGLAS Schedule of Accreditation (LA-2023-0845-C, to ISO/IEC 17025). CMC is the smallest measurement uncertainty we can achieve under accredited conditions.

DC Voltage measuring instrument· UNI-E001 Rev:0
Range / measured quantityMeasurement uncertainty (CMC)
0 mV – 120 mV0.0024 mV
>120 mV – 1.2 V0.0011 %
>1.2 V – 12 V0.0017 %
>12 V – 120 V0.0024 %
>120 V – 1020 V0.0024 %
AC Voltage measuring instruments· UNI-E001 Rev:0
Range / measured quantityMeasurement uncertainty (CMC)
1.0 mV to 12 mV, 3 Hz to 5 Hz1.6%
1.0 mV to 12 mV, >5 Hz to 10 kHz1.0 %
1.0 mV to 12 mV, >10 kHz to 20 kHz0.65 %
1.0 mV to 12 mV, >20 kHz to 50 kHz0.66 %
1.0 mV to 12 mV, >50 kHz to 100 kHz1.7 %
1.0 mV to 12 mV, >100 kHz to 500 kHz3.9 %
12 mV to 120 mV, 3 Hz – 5 Hz0.32 %
12 mV to 120 mV, >5 Hz – 10 kHz0.17 %
12 mV to 120 mV, >10 kHz – 20 kHz0.065 %
12 mV to 120 mV, >20 kHz – 50 kHz0.11 %
12 mV to 120 mV, >50 kHz – 100 kHz0.25 %
12 mV to 120 mV, >100 kHz – 500 kHz1.3 %
120 mV – 1.2 V, 3 Hz – 5 Hz0.42 %
120 mV – 1.2 V, >5 Hz – 10 Hz0.15 %
120 mV – 1.2 V, >10 Hz – 40 Hz0.6 %
120 mV – 1.2 V, >40 Hz – 20 kHz0.13 %
120 mV – 1.2 V, >20 kHz – 50 kHz0.047 %
120 mV – 1.2 V, >50 kHz – 100 kHz0.11 %
120 mV – 1.2 V, >100 kHz – 500 kHz0.41 %
1.2 V – 12 V, 3 Hz – 5 Hz0.33 %
1.2 V – 12 V, >5 Hz – 10 Hz0.5 %
1.2 V – 12 V, >10 Hz – 40 Hz0.6 %
1.2 V – 12 V, >40 Hz – 20 kHz0.018 %
1.2 V – 12 V, >20 kHz – 50 kHz0.035 %
1.2 V – 12 V, >50 kHz – 100 kHz0.081 %
1.2 V – 12 V, > 100 kHz – 500 kHz0.25
12 V – 120 V, >3 Hz – 5 Hz0.32 %
12 V – 120 V, >5 Hz – 10 Hz0.50 %
12 V – 120 V, >10 Hz – 40 Hz0.045 %
12 V – 120 V, >40 Hz – 20 kHz0.092 %
12 V – 120 V, >20 kHz – 50 kHz0.036 %
12 V – 120 V, >50 kHz – 100 kHz0.082 %
120 V – 330 V, 3 Hz – 5 Hz0.50 %
120 V – 330 V, >5 Hz – 10 Hz0.16 %
120 V – 330 V, >10.1 Hz – 20 kHz0.021 %
120 V – 330 V, >20 kHz – 50 kHz0.039 %
120 V – 330 V, >50 kHz – 100 kHz0.17 %
330V – 1020 V, 3 Hz – 5 Hz0.29 %
330V – 1020 V, >5 Hz – 10 Hz0.12 %
330V – 1020 V, >10 Hz – 10 kHz0.04 %
DC Current measuring instruments· UNI-E001 Rev:0
Range / measured quantityMeasurement uncertainty (CMC)
0 µA – 120 µA0.021 µA
>120 µA – 1.2 mA0.045 %
>1.2 mA – 12 mA0.019 %
>12 mA – 120 mA0.02 %
>120 mA – 1.2 A0.029 %
>1.2 A – 3.1 A0.044 %
>3.1 A – 12 A0.041 %
>12 A – 30 A0.11 %
AC Current measuring instruments· UNI-E001 Rev:0
Range / measured quantityMeasurement uncertainty (CMC)
10 µA – 120 µA, >3 Hz – 22.5 Hz0.14 %
10 µA – 120 µA, >22.5 Hz – 45 Hz0.06 %
10 µA – 120 µA, >45 Hz – 1 kHz0.06 %
10 µA – 120 µA, >1 kHz – 5 kHz0.06 %
10 µA – 120 µA, >5 kHz – 10 kHz0.14 %
10 µA – 120 µA, >10 kHz – 30 kHz3.4 %
120 µA – 1.2 mA, 3 Hz – 22.5 Hz0.14 %
120 µA – 1.2 mA, >22.5 Hz – 45 Hz0.11 %
120 µA – 1.2 mA, >45 Hz – 1 kHz0.12 %
120 µA – 1.2 mA, >1 kHz – 5 kHz0.11 %
120 µA – 1.2 mA, >5 kHz – 10 kHz0.24 %
120 µA – 1.2 mA, >10 kHz – 30 kHz4.8 %
1.2 mA – 12 mA, 3 Hz – 45 Hz0.11 %
1.2 mA – 12 mA, >45 Hz – 1 kHz0.11 %
1.2 mA – 12 mA, >1 kHz – 5 kHz0.11 %
1.2 mA – 12 mA, >5 kHz – 10 kHz0.24 %
1.2 mA – 12 mA, >10 kHz – 30 kHz1.4 %
12 mA – 120 mA, 3 Hz – 45 Hz0.11 %
12 mA – 120 mA, >45 Hz – 1 kHz0.06 %
12 mA – 120 mA, >1 kHz – 5 kHz0.018 %
12 mA – 120 mA, >5 kHz – 10 kHz0.24 %
12 mA – 120 mA, >10 kHz – 30 kHz1.4 %
120 mA – 1.2 A, 3 Hz – 45 Hz0.34 %
120 mA – 1.2 A, >45 Hz – 1 kHz0.068 %
120 mA – 1.2 A, >1 kHz – 5 kHz0.09 %
120 mA – 1.2 A, >5 kHz – 10 kHz0.5 %
120 mA – 1.2 A, >10 kHz – 30 kHz0.8 %
1.2 A – 3.1 A, 3 Hz – 45 Hz0.25 %
1.2 A – 3.1 A, >45 Hz – 1 kHz0.06 %
1.2 A – 3.1 A, >1 kHz – 5 kHz0.06 %
1.2 A – 3.1 A, >5 kHz – 10 kHz0.3 %
3.1 A – 12 A, 3 Hz – 45 Hz0.12 %
3.1 A – 12 A, >45 Hz – 1 kHz0.05 %
3.1 A – 12 A, >1 kHz – 5 kHz0.07 %
3.1 A – 12 A, >5 kHz – 10 kHz0.29 %
12 A – 30.2 A, 3 Hz – 45 Hz0.21 %
12 A – 30.2 A, >45 Hz – 1 kHz0.14 %
12 A – 30.2 A, >1 kHz – 5 kHz0.57 %
Resistance measuring instrument· UNI-E001 Rev:0
Range / measured quantityMeasurement uncertainty (CMC)
0 Ω – 12 Ω0.011 Ω
>12 Ω – 120 Ω0.13 %
>120 Ω – 1.2 kΩ0.11 %
>1.2 kΩ – 12 kΩ0.019 %
>12 kΩ – 120 kΩ0.011 %
>120 kΩ – 1.2 MΩ0.011 %
>1.2 MΩ – 12 MΩ0.021 %
>12 MΩ – 120 MΩ0.062 %
>120 MΩ – 1200 MΩ0.42 %
Frequency measuring instruments· UNI-E001 Rev:0
Range / measured quantityMeasurement uncertainty (CMC)
0.01 Hz – 119.99 Hz0.018 %
120.0 Hz – 1199.9 Hz0.0014 %
1.200 kHz – 11.999 kHz0.0011 %
12.00 kHz – 119.99 kHz0.00057 %
120.1 kHz – 1199.9 kHz0.53 %
1.200 MHz – 2.000 MHz0.00027 %
Download the full SINGLAS Schedule (LA-2023-0845-C) — PDF

You can also verify our accreditation on the SAC-SINGLAS directory.

Brands & models

Bench Multimeter brands & models we calibrate

The models customers most commonly send in — not our full capability. Every model is quoted individually; request a quotation and we'll confirm ranges, points and turnaround.

BrandModel
Keysight34465A

Don't see your model? Send us the make and model — or WhatsApp us a photo of the nameplate — and we'll confirm capability and quote.

Questions

Bench Multimeter (Precision) calibration FAQ

How often should a bench multimeter (precision) be calibrated?

Precision bench multimeters are typically calibrated every 12 months. Units used as in-house reference standards may be calibrated every 6 months to tighten the uncertainty budget.

Is bench multimeter (precision) calibration accredited?

Yes. Bench Multimeter (Precision) calibration is covered under our SAC-SINGLAS scope of accreditation (LA-2023-0845-C, ISO/IEC 17025), covering DC/AC voltage to 1020 V, DC/AC current to 30 A, resistance to 1200 MΩ and frequency to 2 MHz. Certificates state the measured values and measurement uncertainty, traceable to national and international standards. Where an instrument falls outside the accredited ranges, we can calibrate it as a traceable service instead.

How long does bench multimeter (precision) calibration take?

Standard turnaround is 5 to 7 working days; express service is 2 to 3 working days. Collection and delivery in Singapore are free for orders above $300.

Which brands of bench multimeter (precision) do you calibrate?

Commonly submitted brands include Keysight. This list covers the models customers most often send in, not our full capability — send us your make and model and we'll confirm whether it falls within our accredited scope or can be calibrated as a traceable service.