SAC-SINGLAS Accredited · ISO/IEC 17025

Ground Bond Continuity Tester Calibration in Singapore

Unitest calibrates ground bond continuity testers in Singapore — including SCS — across 30 mΩ to 1.7 kΩ, under SAC-SINGLAS accreditation LA-2023-0845-C (ISO/IEC 17025). Standard turnaround is 5–7 working days; express service is 2–3 days, with free collection and delivery in Singapore for orders above $300.

Also known as: Electrical Safety Tester · Continuity Tester · Protective Earth Tester

Why calibrate?

Unitest calibrates ground bond continuity testers in Singapore over a range of 30 mΩ to 1.7 kΩ, with SAC-SINGLAS accredited ISO/IEC 17025 certificates. Ground bond testers verify that protective earth conductors have sufficiently low resistance — an error here is a shock hazard.

What you receive

What ground bond continuity tester calibration at Unitest covers

Traceable certificate

Calibration certificate with an unbroken traceability chain to national and international standards, recording the as-found condition before any adjustment.

Stated uncertainty

Results reported with measurement uncertainty, so you know exactly how much confidence each reading carries in your quality system.

5–7 day turnaround

Standard turnaround 5–7 working days; express 2–3 working days on request. Free collection and delivery within Singapore for orders above S$300.

Part of our electrical calibration service, accredited under SAC-SINGLAS LA-2023-0845-C.

How often

How often should a ground bond continuity tester be calibrated?

Ground bond testers should be calibrated at least every 12 months, or whenever used for acceptance testing of electrical equipment under IEC 60950 or IEC 62368.

Accredited ranges

Ground Bond Continuity Tester calibration ranges & measurement uncertainty

The parameters, ranges and calibration & measurement capability (CMC) below are taken from our SAC-SINGLAS Schedule of Accreditation (LA-2023-0845-C, to ISO/IEC 17025). CMC is the smallest measurement uncertainty we can achieve under accredited conditions.

Ground Bond Resistance measuring instruments (fixed points)· UNI-E004 Rev:0
Range / measured quantityMeasurement uncertainty (CMC)
30 mΩ1.3 mΩ
55 mΩ2.1 mΩ
97 mΩ2.3 mΩ
350 mΩ4.1 mΩ
490 mΩ4.4 mΩ
900 mΩ9.2 mΩ
1.7 Ω0.1 Ω
4.7 Ω0.1 Ω
9 Ω0.1 Ω
17 Ω0.1 Ω
47 Ω0.4 Ω
90 Ω0.6 Ω
170 Ω1.2 Ω
470 Ω3.0 Ω
900 Ω5.9 Ω
1.7 kΩ0.08 kΩ
Download the full SINGLAS Schedule (LA-2023-0845-C) — PDF

You can also verify our accreditation on the SAC-SINGLAS directory.

Brands & models

Ground Bond Continuity Tester brands & models we calibrate

The models customers most commonly send in — not our full capability. Every model is quoted individually; request a quotation and we'll confirm ranges, points and turnaround.

BrandModel
SCSCTM051

Don't see your model? Send us the make and model — or WhatsApp us a photo of the nameplate — and we'll confirm capability and quote.

Questions

Ground Bond Continuity Tester calibration FAQ

How often should a ground bond continuity tester be calibrated?

Ground bond testers should be calibrated at least every 12 months, or whenever used for acceptance testing of electrical equipment under IEC 60950 or IEC 62368.

Is ground bond continuity tester calibration accredited?

Yes. Ground Bond Continuity Tester calibration is covered under our SAC-SINGLAS scope of accreditation (LA-2023-0845-C, ISO/IEC 17025), covering 30 mΩ to 1.7 kΩ. Certificates state the measured values and measurement uncertainty, traceable to national and international standards. Where an instrument falls outside the accredited ranges, we can calibrate it as a traceable service instead.

How long does ground bond continuity tester calibration take?

Standard turnaround is 5 to 7 working days; express service is 2 to 3 working days. Collection and delivery in Singapore are free for orders above $300.

Which brands of ground bond continuity tester do you calibrate?

Commonly submitted brands include SCS. This list covers the models customers most often send in, not our full capability — send us your make and model and we'll confirm whether it falls within our accredited scope or can be calibrated as a traceable service.

Related

Related instruments

Browse every instrument type on the Find Your Instrument page.

Need ground bond continuity tester calibration?

Submit your instrument list — we'll confirm capability, turnaround and pricing, no obligation.

Get a QuoteWhatsApp