SAC-SINGLAS Accredited · ISO/IEC 17025

Portable Appliance Tester (PAT) Calibration in Singapore

Unitest calibrates portable appliance testers (PAT testers) in Singapore across ground bond 30 mΩ to 1.7 kΩ, insulation 10 kΩ to 999.9 GΩ and leakage current 0.1 mA to 30 mA, under SAC-SINGLAS accreditation LA-2023-0845-C (ISO/IEC 17025). Standard turnaround is 5–7 working days; express service is 2–3 days, with free collection and delivery in Singapore for orders above $300.

Also known as: PAT Tester · Appliance Tester

Why calibrate?

Unitest calibrates portable appliance testers (PAT testers) in Singapore — verifying earth continuity resistance, insulation resistance and leakage current — with traceable ISO/IEC 17025 certificates. PAT testing results are only defensible if the PAT tester itself is calibrated by an accredited lab.

What you receive

What portable appliance tester (PAT) calibration at Unitest covers

Traceable certificate

Calibration certificate with an unbroken traceability chain to national and international standards, recording the as-found condition before any adjustment.

Stated uncertainty

Results reported with measurement uncertainty, so you know exactly how much confidence each reading carries in your quality system.

5–7 day turnaround

Standard turnaround 5–7 working days; express 2–3 working days on request. Free collection and delivery within Singapore for orders above S$300.

Part of our electrical calibration service, accredited under SAC-SINGLAS LA-2023-0845-C.

How often

How often should a portable appliance tester (PAT) be calibrated?

PAT testers should be calibrated every 12 months. Workplace safety requirements and SS CP 38 typically require that electrical safety test equipment carries a valid calibration certificate.

Accredited ranges

Portable Appliance Tester (PAT) calibration ranges & measurement uncertainty

The parameters, ranges and calibration & measurement capability (CMC) below are taken from our SAC-SINGLAS Schedule of Accreditation (LA-2023-0845-C, to ISO/IEC 17025). CMC is the smallest measurement uncertainty we can achieve under accredited conditions.

Ground Bond Resistance measuring instruments (fixed points)· UNI-E004 Rev:0
Range / measured quantityMeasurement uncertainty (CMC)
30 mΩ1.3 mΩ
55 mΩ2.1 mΩ
97 mΩ2.3 mΩ
350 mΩ4.1 mΩ
490 mΩ4.4 mΩ
900 mΩ9.2 mΩ
1.7 Ω0.1 Ω
4.7 Ω0.1 Ω
9 Ω0.1 Ω
17 Ω0.1 Ω
47 Ω0.4 Ω
90 Ω0.6 Ω
170 Ω1.2 Ω
470 Ω3.0 Ω
900 Ω5.9 Ω
1.7 kΩ0.08 kΩ
High Resistance (Insulation resistance) – measuring instruments· UNI-E004 Rev:0
Range / measured quantityMeasurement uncertainty (CMC)
10 kΩ – 19.999 kΩ0.025 kΩ
20 kΩ – 39.99 kΩ0.047 kΩ
40 kΩ – 99.99 kΩ0.12 kΩ
100 kΩ – 199.99 kΩ0.25 kΩ
200 kΩ – 999.9 kΩ0.47 kΩ
1 MΩ – 1.999 MΩ0.0081 MΩ
2 MΩ – 9.999 MΩ0.01 MΩ
10 MΩ – 19.999 MΩ0.092 MΩ
20 MΩ – 199.99 MΩ0.60 MΩ
200 MΩ – 999.9 MΩ1.4 MΩ
1 GΩ – 1.9 GΩ0.074 GΩ
2 GΩ – 10 GΩ0.077 GΩ
100 GΩ0.15 GΩ
Leakage Current measuring instruments· UNI-E004 Rev:0
Range / measured quantityMeasurement uncertainty (CMC)
0.1 mA – 30 mA1.7 %
Download the full SINGLAS Schedule (LA-2023-0845-C) — PDF

You can also verify our accreditation on the SAC-SINGLAS directory.

Questions

Portable Appliance Tester (PAT) calibration FAQ

How often should a portable appliance tester (PAT) be calibrated?

PAT testers should be calibrated every 12 months. Workplace safety requirements and SS CP 38 typically require that electrical safety test equipment carries a valid calibration certificate.

Is portable appliance tester (PAT) calibration accredited?

Yes. Portable Appliance Tester (PAT) calibration is covered under our SAC-SINGLAS scope of accreditation (LA-2023-0845-C, ISO/IEC 17025), covering ground bond 30 mΩ to 1.7 kΩ, insulation 10 kΩ to 999.9 GΩ and leakage current 0.1 mA to 30 mA. Certificates state the measured values and measurement uncertainty, traceable to national and international standards. Where an instrument falls outside the accredited ranges, we can calibrate it as a traceable service instead.

How long does portable appliance tester (PAT) calibration take?

Standard turnaround is 5 to 7 working days; express service is 2 to 3 working days. Collection and delivery in Singapore are free for orders above $300.

Can you calibrate my brand of portable appliance tester (PAT)?

Almost certainly — the makes listed on this site are simply the ones customers most commonly send in. Send us the make and model and our engineers will confirm whether it falls within our accredited scope or can be calibrated as a traceable service.

Related

Related instruments

Browse every instrument type on the Find Your Instrument page.

Need portable appliance tester (PAT) calibration?

Submit your instrument list — we'll confirm capability, turnaround and pricing, no obligation.

Get a QuoteWhatsApp