SAC-SINGLAS Accredited · ISO/IEC 17025

Power Quality Analyzer Calibration in Singapore

Unitest calibrates power quality and harmonic analyzers in Singapore — including Hioki and Fluke — across AC voltage to 1020 V, AC current to 30.2 A and AC power 0.02 W to 1500 kW, under SAC-SINGLAS accreditation LA-2023-0845-C (ISO/IEC 17025). Standard turnaround is 5–7 working days; express service is 2–3 days, with free collection and delivery in Singapore for orders above $300.

Also known as: Harmonic Analyzer · Power Quality/Harmonic Analyzer · PQ Analyzer

Why calibrate?

Unitest calibrates power quality analyzers and harmonic analyzers in Singapore, verifying AC voltage, AC current, frequency and power measurements against traceable ISO/IEC 17025 references. Power quality data is used for energy auditing and compliance — calibration ensures the data can be trusted.

What you receive

What power quality analyzer calibration at Unitest covers

Traceable certificate

Calibration certificate with an unbroken traceability chain to national and international standards, recording the as-found condition before any adjustment.

Stated uncertainty

Results reported with measurement uncertainty, so you know exactly how much confidence each reading carries in your quality system.

5–7 day turnaround

Standard turnaround 5–7 working days; express 2–3 working days on request. Free collection and delivery within Singapore for orders above S$300.

Part of our electrical calibration service, accredited under SAC-SINGLAS LA-2023-0845-C.

How often

How often should a power quality analyzer be calibrated?

Power quality analyzers are typically calibrated every 12 months. Instruments used for energy audit reporting or SS 473 compliance should carry a current certificate.

Accredited ranges

Power Quality Analyzer calibration ranges & measurement uncertainty

The parameters, ranges and calibration & measurement capability (CMC) below are taken from our SAC-SINGLAS Schedule of Accreditation (LA-2023-0845-C, to ISO/IEC 17025). CMC is the smallest measurement uncertainty we can achieve under accredited conditions.

AC Voltage measuring instruments· UNI-E001 Rev:0
Range / measured quantityMeasurement uncertainty (CMC)
1.0 mV to 12 mV, 3 Hz to 5 Hz1.6%
1.0 mV to 12 mV, >5 Hz to 10 kHz1.0 %
1.0 mV to 12 mV, >10 kHz to 20 kHz0.65 %
1.0 mV to 12 mV, >20 kHz to 50 kHz0.66 %
1.0 mV to 12 mV, >50 kHz to 100 kHz1.7 %
1.0 mV to 12 mV, >100 kHz to 500 kHz3.9 %
12 mV to 120 mV, 3 Hz – 5 Hz0.32 %
12 mV to 120 mV, >5 Hz – 10 kHz0.17 %
12 mV to 120 mV, >10 kHz – 20 kHz0.065 %
12 mV to 120 mV, >20 kHz – 50 kHz0.11 %
12 mV to 120 mV, >50 kHz – 100 kHz0.25 %
12 mV to 120 mV, >100 kHz – 500 kHz1.3 %
120 mV – 1.2 V, 3 Hz – 5 Hz0.42 %
120 mV – 1.2 V, >5 Hz – 10 Hz0.15 %
120 mV – 1.2 V, >10 Hz – 40 Hz0.6 %
120 mV – 1.2 V, >40 Hz – 20 kHz0.13 %
120 mV – 1.2 V, >20 kHz – 50 kHz0.047 %
120 mV – 1.2 V, >50 kHz – 100 kHz0.11 %
120 mV – 1.2 V, >100 kHz – 500 kHz0.41 %
1.2 V – 12 V, 3 Hz – 5 Hz0.33 %
1.2 V – 12 V, >5 Hz – 10 Hz0.5 %
1.2 V – 12 V, >10 Hz – 40 Hz0.6 %
1.2 V – 12 V, >40 Hz – 20 kHz0.018 %
1.2 V – 12 V, >20 kHz – 50 kHz0.035 %
1.2 V – 12 V, >50 kHz – 100 kHz0.081 %
1.2 V – 12 V, > 100 kHz – 500 kHz0.25
12 V – 120 V, >3 Hz – 5 Hz0.32 %
12 V – 120 V, >5 Hz – 10 Hz0.50 %
12 V – 120 V, >10 Hz – 40 Hz0.045 %
12 V – 120 V, >40 Hz – 20 kHz0.092 %
12 V – 120 V, >20 kHz – 50 kHz0.036 %
12 V – 120 V, >50 kHz – 100 kHz0.082 %
120 V – 330 V, 3 Hz – 5 Hz0.50 %
120 V – 330 V, >5 Hz – 10 Hz0.16 %
120 V – 330 V, >10.1 Hz – 20 kHz0.021 %
120 V – 330 V, >20 kHz – 50 kHz0.039 %
120 V – 330 V, >50 kHz – 100 kHz0.17 %
330V – 1020 V, 3 Hz – 5 Hz0.29 %
330V – 1020 V, >5 Hz – 10 Hz0.12 %
330V – 1020 V, >10 Hz – 10 kHz0.04 %
AC Current measuring instruments· UNI-E001 Rev:0
Range / measured quantityMeasurement uncertainty (CMC)
10 µA – 120 µA, >3 Hz – 22.5 Hz0.14 %
10 µA – 120 µA, >22.5 Hz – 45 Hz0.06 %
10 µA – 120 µA, >45 Hz – 1 kHz0.06 %
10 µA – 120 µA, >1 kHz – 5 kHz0.06 %
10 µA – 120 µA, >5 kHz – 10 kHz0.14 %
10 µA – 120 µA, >10 kHz – 30 kHz3.4 %
120 µA – 1.2 mA, 3 Hz – 22.5 Hz0.14 %
120 µA – 1.2 mA, >22.5 Hz – 45 Hz0.11 %
120 µA – 1.2 mA, >45 Hz – 1 kHz0.12 %
120 µA – 1.2 mA, >1 kHz – 5 kHz0.11 %
120 µA – 1.2 mA, >5 kHz – 10 kHz0.24 %
120 µA – 1.2 mA, >10 kHz – 30 kHz4.8 %
1.2 mA – 12 mA, 3 Hz – 45 Hz0.11 %
1.2 mA – 12 mA, >45 Hz – 1 kHz0.11 %
1.2 mA – 12 mA, >1 kHz – 5 kHz0.11 %
1.2 mA – 12 mA, >5 kHz – 10 kHz0.24 %
1.2 mA – 12 mA, >10 kHz – 30 kHz1.4 %
12 mA – 120 mA, 3 Hz – 45 Hz0.11 %
12 mA – 120 mA, >45 Hz – 1 kHz0.06 %
12 mA – 120 mA, >1 kHz – 5 kHz0.018 %
12 mA – 120 mA, >5 kHz – 10 kHz0.24 %
12 mA – 120 mA, >10 kHz – 30 kHz1.4 %
120 mA – 1.2 A, 3 Hz – 45 Hz0.34 %
120 mA – 1.2 A, >45 Hz – 1 kHz0.068 %
120 mA – 1.2 A, >1 kHz – 5 kHz0.09 %
120 mA – 1.2 A, >5 kHz – 10 kHz0.5 %
120 mA – 1.2 A, >10 kHz – 30 kHz0.8 %
1.2 A – 3.1 A, 3 Hz – 45 Hz0.25 %
1.2 A – 3.1 A, >45 Hz – 1 kHz0.06 %
1.2 A – 3.1 A, >1 kHz – 5 kHz0.06 %
1.2 A – 3.1 A, >5 kHz – 10 kHz0.3 %
3.1 A – 12 A, 3 Hz – 45 Hz0.12 %
3.1 A – 12 A, >45 Hz – 1 kHz0.05 %
3.1 A – 12 A, >1 kHz – 5 kHz0.07 %
3.1 A – 12 A, >5 kHz – 10 kHz0.29 %
12 A – 30.2 A, 3 Hz – 45 Hz0.21 %
12 A – 30.2 A, >45 Hz – 1 kHz0.14 %
12 A – 30.2 A, >1 kHz – 5 kHz0.57 %
AC Power measuring instruments· UNI-E001 Rev:0
Range / measured quantityMeasurement uncertainty (CMC)
0.02 W – 0.5 W0.60 %
>0.5 W – 5 W0.14%
>5 W – 50 W0.23 %
>50 W – 1000 W0.7 %
>1 kW – 5 kW2.3 %
>5 kW – 20 kW2.3 %
>20 kW – 30 kW3 %
With Coil 30 kW – 1500 kW4 %
Frequency measuring instruments· UNI-E001 Rev:0
Range / measured quantityMeasurement uncertainty (CMC)
0.01 Hz – 119.99 Hz0.018 %
120.0 Hz – 1199.9 Hz0.0014 %
1.200 kHz – 11.999 kHz0.0011 %
12.00 kHz – 119.99 kHz0.00057 %
120.1 kHz – 1199.9 kHz0.53 %
1.200 MHz – 2.000 MHz0.00027 %
Download the full SINGLAS Schedule (LA-2023-0845-C) — PDF

You can also verify our accreditation on the SAC-SINGLAS directory.

Brands & models

Power Quality Analyzer brands & models we calibrate

The models customers most commonly send in — not our full capability. Every model is quoted individually; request a quotation and we'll confirm ranges, points and turnaround.

BrandModel
Fluke345 PQ
Fluke1775
HiokiPQ3100
HiokiPQ3198
HiokiPW3198

Don't see your model? Send us the make and model — or WhatsApp us a photo of the nameplate — and we'll confirm capability and quote.

Questions

Power Quality Analyzer calibration FAQ

How often should a power quality analyzer be calibrated?

Power quality analyzers are typically calibrated every 12 months. Instruments used for energy audit reporting or SS 473 compliance should carry a current certificate.

Is power quality analyzer calibration accredited?

Yes. Power Quality Analyzer calibration is covered under our SAC-SINGLAS scope of accreditation (LA-2023-0845-C, ISO/IEC 17025), covering AC voltage to 1020 V, AC current to 30.2 A and AC power 0.02 W to 1500 kW. Certificates state the measured values and measurement uncertainty, traceable to national and international standards. Where an instrument falls outside the accredited ranges, we can calibrate it as a traceable service instead.

How long does power quality analyzer calibration take?

Standard turnaround is 5 to 7 working days; express service is 2 to 3 working days. Collection and delivery in Singapore are free for orders above $300.

Which brands of power quality analyzer do you calibrate?

Commonly submitted brands include Fluke and Hioki. This list covers the models customers most often send in, not our full capability — send us your make and model and we'll confirm whether it falls within our accredited scope or can be calibrated as a traceable service.